Nominal pipe size does not describe the whole measuring range of a water meter. Flow ratings explain where the meter is intended to operate and help buyers compare alternatives without confusing starting flow, measuring range and accuracy.
Four reference flows
Q1 denotes minimum flow and Q2 transitional flow. Q3 denotes permanent flow, while Q4 denotes overload flow. These values describe different parts of the operating range. Q4 should not be interpreted as a normal continuous design point. The applicable standard edition, accuracy class and approved conditions determine how error limits are assessed across the range.
For a WE RICH product comparison, the LXC DN15–DN50 ultrasonic water meter with valve control combines ultrasonic measurement with remote valve control for residential supply points.
For a WE RICH product comparison, the LXC-D DN50–DN300 ultrasonic bulk water meter addresses larger-diameter water measurement at network and bulk supply points.
Calculate the R ratio correctly
R = Q3/Q1. For an illustrative Q3 of 4 m³/h and R400, Q1 equals 0.01 m³/h, or 10 L/h. With the same Q3 and R800, Q1 would be 5 L/h. Compare R values together with Q3: two meters with different permanent flows can have the same R but different minimum flows. These examples are calculations, not product ratings.
Use flow ratings in procurement
Request the exact meter designation, approved mounting orientation and test evidence. Compare expected night consumption with Q1 and expected sustained demand with Q3. Brief peaks need separate review against the overload conditions. A meter that displays a small flow is not necessarily meeting specified accuracy at that flow. Keep display resolution and starting-flow figures separate from the approved measuring range.
Practical checklist
- Keep all flow units consistent.
- Record Q3 and R together.
- Check the model certificate and installation conditions.
Frequently asked questions
Is R an accuracy percentage?
No. It is the dimensionless ratio of permanent to minimum flow.
Can I size a meter from Q4?
Q4 is an overload rating. Review normal service against the permanent-flow and installation requirements.
Is Q1 the starting flow?
No. Starting response and verified performance at Q1 are different characteristics.
Related articles
References and technical reading
Product capabilities depend on the model and its documentation. Confirm installation and performance requirements for the project.