WASIONWater solution powered by WE RICHNewsroom
← All products
LXC-D DN50–DN300 Ultrasonic Bulk Water Meter

WE RICH / BULK METERING

LXC-D DN50–DN300 Ultrasonic Bulk Water Meter

Ultrasonic measurement for larger-diameter water networks.

DN50–DN300Diameter range
UltrasonicMeasurement
Bulk meteringApplication
Product Description

The LXC ultrasonic series measures water for pipeline and household billing and DMA district management. The listed standards are OIML R49, ISO 4064 and EN 14154.

Key features
  • Up to 500:1 range, low starting flow and high measurement accuracy.
  • Four-channel, dual-plane measurement throughout the series.
  • IP68 integrated construction; 10-year service life.
  • No moving mechanical elements; low pressure loss.
  • Combined flow, temperature and pressure measurement; seamless stainless-steel pipe.
Technical specifications

Model and supply information

ItemValue
Original brandWinmeter
ModelDN50–DN300 Ultrasonic Bulk Water Meter
StandardsOIML R49 / ISO 4064 / EN 14154
PackagingCarton

Technical characteristics — diameter-specific values

ParameterDN50DN80DN100DN150DN200DN250DN300
Q3 (m³/h)4010016040063010001600
Starting flow (m³/h)0.0090.0240.0360.0880.1270.2270.353

Technical characteristics — common values

ParameterValue
MeasurementUltrasonic
Q3/Q1R400 / R500
AccuracyClass 2; Q1 ≤ Q < Q2: ±5%; Q2 ≤ Q ≤ Q4: ±2% at 0.1–30°C; ±3% above 30°C
Volume display−999999.9 to 9999999.9 m³
Flow display−9999.999 to 99999.999 m³/h
Temperature classT30, T50
Pressure classMAP16 (16 bar)
Pressure-loss classΔp10 (0.1 bar)
OrientationH/V
Installation sensitivityU5/D3
EM/environment classE2, O
MaterialSS
Environment−25 to 55°C; ≤100% RH
ProtectionIP68

Electronic characteristics

ParameterValue
PowerReplaceable lithium battery
Voltage3.6 V
Local interfaceOptical, EN13757
Remote interfacesRS485; Wired M-Bus (OMS); GPRS; NB-IoT through DTU
Data rates2.4 / 4.8 / 9.6 kbps
ProtocolsModbus, M-Bus (EN13757.3), private protocol

Dimensions (mm)

ParameterDN50DN80DN100DN150DN200DN250DN300
L200225250300350450500
D165200220285340405460
D1125160180240295355410
n–Φ4–188–188–188–2212–2212–2612–26

Communications

  • RS485/M-Bus and GPRS/4G are listed in the function section.

Monitoring and logs

  • Records magnetic interference, low battery, reverse flow, stopped meter, leakage, valve failures and tampering involving covers or tilt.
  • Hourly, daily and monthly history; top-up and valve-operation event records.

Security

  • AES-128, STS and communication protection.

Source certificate list

  • OIML R49, ISO4064, EN14154.