WASIONWater solution powered by WE RICHNewsroom
← All products
LXG Electromagnetic Water Meter

WE RICH / BULK METERING

LXG Electromagnetic Water Meter

Electromagnetic measurement for water-network applications.

DN40–DN300Diameter range
ElectromagneticMeasurement
RS485 / 4GCommunication
Product Description

LXG electromagnetic water meters provide a Q3/Q1 range up to 400, typical battery service exceeding six years, a compact low-profile design, a polymer flow tube and resin-encapsulated sensor construction. Internal-humidity alarms and an optional integrated pressure sensor support network monitoring.

Key features
  • DN40–DN300
  • RS485 / 4G communication
  • Typical six-year battery life
Technical specifications

Technical specifications

CategoryItemValue
Wetted materialsElectrodes316L stainless steel
Wetted materialsLiningPolymer flow tube
TransmitterMountingIntegrated with sensor
TransmitterEnclosureIP68, 304 stainless steel, polyamide-glass window
PowerTypesIntegrated 3.6 V lithium battery; or 3.6 V battery + 24 VDC
PowerBattery lifeTypically 6 years at 0–50°C / 32–122°F, measuring every 9 seconds and transmitting remotely every 6 hours.
CommunicationWired protocolsRS485: Modbus / custom protocol
CommunicationWireless4G
CommunicationAntenna optionsIntegrated antenna or external square antenna
AlertsMonitoringLow battery, empty pipe, excitation, reverse flow, instantaneous flow min/max, pressure min/max, temperature and humidity.

Dimensions and weight

SizeL (mm)Outside diameter (mm)H (mm)Weight (kg)
DN 40200 (78.7)150 (59.1)292 (115)11
DN 50200 (78.7)165 (65)300 (118.1)13
DN 65200 (78.7)185 (72.8)325 (128)14
DN 80200 (78.7)200 (78.7)337 (132.7)21
DN 100250 (98.4)220 (86.6)357 (140.6)21
DN 125250 (98.4)250 (98.4)383 (150.8)23
DN 150300 (118.1)285 (112.2)413 (162.6)34
DN 200350 (137.8)340 (133.9)459 (180.7)47
DN 250450 (177.2)395 (155.5)524 (206.3)65
DN 300500 (196.9)445 (175.2)574 (226)88

ISO 4064:2024 flow requirements — R160

Sizein.RQ4 m³/h (Ugal/min)Q3 m³/h (Ugal/min)Q2 m³/h (Ugal/min)Q1 m³/h (Ugal/min)
DN 4011.5160331.3 (138)25 (110)0.25 (1.1)0.16 (0.7)
DN 50216050 (220)40 (176)0.4 (1.8)0.25 (1.1)
DN 652.516078.8 (347)63 (277)0.63 (2.8)0.39 (1.7)
DN 803160125 (550)100 (440)1 (4.4)0.63 (2.8)
DN 1004160200 (881)160 (704)1.6 (7)1 (4.4)
DN 1255160312 (1374)250 (1101)2.5 (11)1.56 (6.9)
DN 1506160500 (2201)400 (1761)4 (18)2.5 (11)
DN 2008160787.5 (3467)630 (2774)6.3 (28)3.94 (17)
DN 250101601250 (5504)1000 (4403)10 (44)6.25 (28)
DN 300121602000 (8806)1600 (7045)16 (70)10 (44)

ISO 4064:2024 flow requirements — R250

Sizein.RQ4 m³/h (Ugal/min)Q3 m³/h (Ugal/min)Q2 m³/h (Ugal/min)Q1 m³/h (Ugal/min)
DN 401.525031.3 (138)25 (110)0.16 (0.7)0.1 (0.44)
DN 50225050 (220)40 (176)0.26 (1.1)0.16 (0.7)
DN 652.525078.8 (347)63 (277)0.4 (1.8)0.25 (1.1)
DN 803250125 (550)100 (440)0.64 (2.8)0.4 (1.8)
DN 1004250200 (881)160 (704)1.02 (4.5)0.64 (2.8)
DN 1255250312 (1374)250 (1101)1.6 (7)1 (4.4)
DN 1506250500 (2201)400 (1761)2.56 (11)1.6 (7)
DN 2008250787.5 (3467)630 (2774)4.03 (18)2.52 (11)
DN 250102501250 (5504)1000 (4403)6.4 (28)4 (18)
DN 300122502000 (8806)1600 (7045)10.24 (45)6.4 (28)

ISO 4064:2024 flow requirements — R400

Sizein.RQ4 m³/h (Ugal/min)Q3 m³/h (Ugal/min)Q2 m³/h (Ugal/min)Q1 m³/h (Ugal/min)
DN 401.540031.3 (138)25 (110)0.1 (0.44)0.063 (0.28)
DN 50240050 (220)40 (176)0.16 (0.7)0.1 (0.44)
DN 652.540078.8 (347)63 (277)0.252 (1.1)0.158 (0.7)
DN 803400125 (550)100 (440)0.4 (1.8)0.25 (1.1)
DN 1004400200 (881)160 (704)0.64 (2.8)0.4 (1.8)
DN 1255400312 (1374)250 (1101)1 (4.4)0.625 (2.8)
DN 1506400500 (2201)400 (1761)1.6 (7)1 (4.4)
DN 2008400787.5 (3467)630 (2774)2.52 (11)1.575 (6.9)
DN 250104001250 (5504)1000 (4403)4 (18)2.5 (11)
DN 300124002000 (8806)1600 (7045)6.4 (28)4 (18)

Design and functions

  • Self-adhesive moulded coils and injection-moulded guide tubes improve circuit fit, magnetic-field stability and long-term measurement consistency.
  • Stamped silicon-steel magnetic plates concentrate the field while lowering energy consumption.
  • The integrated lithium battery supports locations without external power. DC-powered versions retain the battery for backup during outages, with battery life extended from four to more than six years.
  • The PPS flow tube avoids rubber-lining ageing associated with chloride ions.
  • Flow calibration is offered with ISO17025 accreditation and ILAC MRA recognition.
  • Patented resin injection removes residual air, insulates coils and secures internal parts against transport or installation vibration.
  • Local and remote alarms monitor empty pipes, reverse flow and abnormal pressure, temperature or flow. Users can customise flow, pressure and temperature thresholds.

Installation requirements

  • Install horizontally with the flow arrow aligned and the register facing upward.
  • Flush the pipeline before installation.
  • Keep the meter completely filled with water during operation.